logo
제품 소개PSA 산소 발생기

35Nm³/h 95% Purity PSA Oxygen Generator for Wastewater Treatment Pressure Swing Adsorption Oxygen Plant

제가 지금 온라인 채팅 해요

35Nm³/h 95% Purity PSA Oxygen Generator for Wastewater Treatment Pressure Swing Adsorption Oxygen Plant

35Nm³/h 95% Purity PSA Oxygen Generator for Wastewater Treatment Pressure Swing Adsorption Oxygen Plant
35Nm³/h 95% Purity PSA Oxygen Generator for Wastewater Treatment Pressure Swing Adsorption Oxygen Plant 35Nm³/h 95% Purity PSA Oxygen Generator for Wastewater Treatment Pressure Swing Adsorption Oxygen Plant 35Nm³/h 95% Purity PSA Oxygen Generator for Wastewater Treatment Pressure Swing Adsorption Oxygen Plant 35Nm³/h 95% Purity PSA Oxygen Generator for Wastewater Treatment Pressure Swing Adsorption Oxygen Plant

큰 이미지 :  35Nm³/h 95% Purity PSA Oxygen Generator for Wastewater Treatment Pressure Swing Adsorption Oxygen Plant

제품 상세 정보:
원래 장소: 중국
브랜드 이름: GNEE
인증: SGS
결제 및 배송 조건:
최소 주문 수량: ≥1sets
가격: According to the product
배달 시간: 운송 시간 : Est. 17-24 일
지불 조건: MoneyGram,웨스턴 유니온,T/T,D/P,D/A,L/C

35Nm³/h 95% Purity PSA Oxygen Generator for Wastewater Treatment Pressure Swing Adsorption Oxygen Plant

설명
에너지 소비: 0.3 - 0.8kW/Nm3 기원: 중국
재료: 탄소강/스테인레스 스틸 산출: 950Nm3/h(GOX)
질소 출력: 170Nm3/hr 공기 공급원: 압축 공기
응용: 의료, 산업, 폐수 처리, 양식업 특징: 고압
상태: 산소 플랜트 산소 이슬점: -40 -또는 -60 ℃
소비: 에너지 절약 핵심 구성요소: 산소 발생기
강조하다:

35Nm³/h PSA Oxygen Generator

,

95% Purity Pressure Swing Adsorption Oxygen Plant

,

Wastewater Treatment Oxygen Plant Generator

35Nm³/h 95% Purity PSA Oxygen System for Wastewater Treatment
Wastewater biological treatment, the core process in municipal and industrial wastewater plants, relies on aeration systems to supply oxygen for aerobic microorganisms that decompose organic pollutants, nitrify ammonia nitrogen, and purify water quality. The PSA oxygen generator operates on pressure swing adsorption technology to physically separate oxygen from ambient air using high-efficiency molecular sieves, delivering 95% pure oxygen with no chemical additives.
Technical Specifications
Capacity (Nm³/h) Purity O₂ Outlet Pressure (Mpa) Inlet/Outlet Connections (mm) Dimensions (mm)
2.2 - 395%±1%0.3 - 0.5DN15/G1 21200×1000×1840
3.5 - 595%±1%0.3 - 0.5DN20/G1 21350×1200×2050
6 - 795%±1%0.3 - 0.5DN25/G1 21500×1350×2350
8 - 1095%±1%0.3 - 0.5DN25/G1 21750×1550×2300
11 - 1395%±1%0.3 - 0.5DN25/G1 21750×1550×2300
14 - 1595%±1%0.3 - 0.5DN40/G1 21850×1825×2350
16 - 1795%±1%0.3 - 0.5DN40/G1 21850×1825×2350
18 - 2095%±1%0.3 - 0.5DN40/G1 22000×1900×2350
21 - 2595%±1%0.3 - 0.5DN40/G1 22100×2050×2400
26 - 3095%±1%0.3 - 0.5DN40/G1 22100×2050×2400
31 - 3595%±1%0.3 - 0.5DN50/G12000×1300×2400
36 - 4295%±1%0.3 - 0.5DN50/G12000×1300×2800
43 - 4695%±1%0.3 - 0.5DN50/G12000×1300×2800
47 - 5295%±1%0.3 - 0.5DN50/G11800×1700×2400
53 - 5695%±1%0.3 - 0.5DN50/G1-1 22100×1800×2600
57 - 6395%±1%0.3 - 0.5DN65/G1-1 22200×1500×2700
398%±1%0.5 - 1.0DN20/G1 2/
598%±1%0.5 - 1.0DN20/G1 2/
1098%±1%0.5 - 1.0DN25/G1 2/
1598%±1%0.5 - 1.0DN25/G1 2/
2098%±1%0.5 - 1.0DN40/G1 2/
2598%±1%0.5 - 1.0DN40/G1 2/
3098%±1%0.5 - 1.0DN50/G1 2/
4098%±1%0.5 - 1.0DN50/G1/
35Nm³/h 95% Purity PSA Oxygen Generator for Wastewater Treatment Pressure Swing Adsorption Oxygen Plant 0 35Nm³/h 95% Purity PSA Oxygen Generator for Wastewater Treatment Pressure Swing Adsorption Oxygen Plant 1 35Nm³/h 95% Purity PSA Oxygen Generator for Wastewater Treatment Pressure Swing Adsorption Oxygen Plant 2
PSA Oxygen Generator vs Traditional Aeration Methods
Wastewater aeration requires high oxygen transfer, low energy consumption, and stable operation—all achieved by PSA oxygen generators:
  • Efficiency vs Air Blowers: Traditional air blowers supply 21% oxygen, with 79% nitrogen increasing aeration volume and energy waste. 95% pure oxygen raises DO levels in bioreactors from 2-3mg/L to 6-8mg/L, accelerating microbial degradation and reducing aeration time by 25%.
  • Cost vs Liquid Oxygen: Liquid oxygen for aeration costs approximately $120/day for a 5,000 m³/day plant. The PSA system's daily electricity cost is only about $25.92, saving approximately $34,608 annually.
  • Stability vs Oxygen Cylinders: Oxygen cylinders require frequent replacement, leading to DO fluctuations. The PSA system operates 24/7 with a 0.8Nm³ buffer tank ensuring stable DO levels for microbial growth.
PSA vs VPSA Oxygen Generators for Wastewater Treatment
Both technologies belong to pressure swing adsorption oxygen plants, but their wastewater applicability differs:
  • PSA System: Compact size, fast start-up (≤5 minutes), and low maintenance—ideal for medium-scale plants (5,000-10,000 m³/day) with fluctuating organic loads.
  • VPSA System: Uses vacuum regeneration for lower energy consumption but has larger size, higher initial investment, and longer start-up time. Suitable for large plants (≥20,000 m³/day).
  • Key Advantage: For 70% of wastewater plants, the PSA system's balance of cost, flexibility, and efficiency makes it more practical than VPSA.
Conclusion
The 35Nm³/h 95% purity PSA System for Oxygen revolutionizes wastewater aeration by combining advanced PSA technology with wastewater-specific design. Its high oxygen transfer efficiency, low energy consumption, and corrosion resistance solve the core challenges of traditional aeration methods, while delivering significant long-term savings for medium-scale wastewater plants.
For wastewater plants aiming to improve treatment efficiency, reduce operating costs, and comply with environmental policies, this PSA system is a reliable, future-oriented investment that plays a critical role in promoting green, efficient development of the wastewater treatment industry.
Email: info@gneeheatex.com
WhatsApp (WeChat): +86 15824687445

연락처 세부 사항
Henan Gnee New Materials Co., Ltd.

담당자: Mrs. Kelly

전화 번호: +86 15824687445

회사에 직접 문의 보내기 (0 / 3000)